Presentasi sedang didownload. Silahkan tunggu

Presentasi sedang didownload. Silahkan tunggu

PLTU 2 x 3 MW NIAS SELATAN SITE SELECTION with PLN CABANG NIAS and PLN Enjiniring 16-20 March 2010.

Presentasi serupa


Presentasi berjudul: "PLTU 2 x 3 MW NIAS SELATAN SITE SELECTION with PLN CABANG NIAS and PLN Enjiniring 16-20 March 2010."— Transcript presentasi:

1 PLTU 2 x 3 MW NIAS SELATAN SITE SELECTION with PLN CABANG NIAS and PLN Enjiniring 16-20 March 2010

2 Peta GPS PULAU NIAS

3 LOKASI IPP PLTU NIAS 2x7 MW

4 FOTO LOKASI IPP PLTU NIAS 2x7 MW GUNUNG SITOLI UTARA

5 LOKASI 2 PLTU NIAS SELATAN 2x3 MW LOKASI 1 PLTU NIAS SELATAN 2x3 MW

6 FOTO LOKASI 1 DESA SIWALUBANUA

7 FOTO LOKASI 2 DESA TETEZOU

8 LOKASI ALT 1 PLTU NIAS SELATAN 2x3 MW LOKASI 3 PLTU NIAS SELATAN 2x3 MW

9 FOTO LOKASI 3 DAN ALT - 1 DESA BALOHO LOKASI 3 PLTU NIAS SELATAN 2x3 MW LOKASI ALT - 1 PLTU NIAS SELATAN 2x3 MW

10 LOKASI ALT 2 PLTU NIAS SELATAN 2x3 MW

11 FOTO LOKASI ALT - 2 GUNUNG SITOLI IDANOI

12 LOKASI ALT 3 PLTU NIAS SELATAN 2x3 MW

13 FOTO LOKASI ALT - 3 DESA BOZIHONA

14 Rencana Lokasi PLTU IPP PLTU NIAS 2x7 MW LOCATION 1LOCATION 2LOCATION 3 VillageDesa AfiaDesa SiwalubanuaDesa Tetezou Desa Baloho (Teluk) Sub District Gunung Sitoli Utara Lahusa Teluk Dalam DistrictKota Gunung SitoliNias Selatan Coordinate N1 24 08.6 E97 32 31.2 N0 48 21.0 E97 54 26.8 N0 45 56.3 E97 53 26.0 N0 33 33.5 E97 48 17.2 DIUSULKAN OLEH PLN WILAYAH SUMUT LOKASI DI GUNUNG SITOLI UTARA UNTUK RENCANA IPP; PLTU NIAS 2x7 MW LOKASI 1,2 DAN 3 UNTUK PLTU NIAS SELATAN 2x3 MW

15 Summary of Site Selection ASPECTS IPP PLTU NIAS 2x7 MW LOCATION 1LOCATION 2LOCATION 3 Technical69.2064.0464.9565.22 Socio-Economic32.0026.0030.0032.00 Environmental37.9035.9034.9039.90 TOTAL139.10125.94129.85137.12

16 Rencana Lokasi Alternatif PLTU DI SURVEY OLEH PLN CABANG NIAS DAN PLN E UNTUK RENCANA PLTU NIAS SELATAN 2x3 MW ALTERNATIF 1 ALTERNATIF 2ALTERNATIF 3 VillageDesa BalohoDesa SimanereDesa Bazihona Sub DistrictTeluk Dalam Gunung Sitoli Idanoi Hidanogawo DistrictNias SelatanGunung SitoliNias Coordinate N0 32 56.0 E97 48 34.8 N1 12 18.5 E97 40 47.1 N1 05 54.7 E97 49 53.4

17 Summary of Site Selection ASPECTSALT 1ALT 2ALT 3 Technical65.0265.4259.62 Socio-Economic32.0040.0028.00 Environmental39.9036.9033.90 TOTAL136.92142.32121.52

18 diskusi DARI EMPAT (4) LOKASI YANG DIUSULKAN OLEH PLN WILAYAH SUMUT, PADA DI DESA AFIA, KECAMATAN GUNUNG SITOLI UTARA, AKAN DIPERGUNAKAN UNTUK IPP PLTU NIAS 2x7 MW. UNTUK PLTU NIAS SELATAN 2x3 MW, BERDASARKAN PEMBOBOTAN, LOKASI 3 (DESA BALOHO, KECAMATAN TELUK DALAM) LEBIH LAYAK DIBANDINGKAN LOKASI 1 DAN 2, AKAN TETAPI SECARA VISUAL, KONDISI LAUT DI LOKASI 3 TERDAPAT BARRIER TERUMBU KARANG (± 500 M DARI GARIS PANTAI), YANG DIKHAWATIRKAN DAPAT MENGHAMBAT AKSES COAL BARGE, SEHINGGA PLN-E BERINISIATIF UNTUK MENCARI LOKASI ALTERNATIF DI SEKITAR LOKASI 4. DARI HASIL SURVEY DIPEROLEH LOKASI ATERNATIF 1 (± 1.5 KM DARI LOKASI 3) YANG SECARA VISUAL KEBERADAAN TERUMBU KARANG LEBIH SEDIKIT DIBANDINGKAN LOKASI 3. DARI PENJELASAN DIATAS DAPAT DISIMPULKAN BAHWA UNTUK PLTU NIAS SELATAN 2x3 MW, LOKASI ALTERNATIF 1 LEBIH LAYAK DIBANDINGKAN LOKASI 3 MESKIPUN SECARA PEMBOBOTAN LOKASI ATERNATIF 1 (136.92) LEBIH SEDIKIT DIBANDINGKAN LOKASI 3 (137.12).

19 diskusi PADA SITE SURVEY KALI INI PLN-E JUGA MENDAPAT MASUKAN DARI PLN CABANG NIAS UNTUK MENCARI ALTERNATIF LOKASI PLTU DENGAN MEMPERTIMBANGAN BEBAN PENDISTRIBUSIAN KEBUTUHAN LISTRIK DI PULAU NIAS, DENGAN HARAPAN LOKASI PLTU NIAS SELATAN 2x3 MW DAPAT DIPINDAHKAN KE LOKASI TERSEBUT, SEHINGGA DIPEROLEH LOKASI ALTERNATIF 2 DAN 3. SECARA VISUAL DAN PEMBOBOTAN, LOKASI ALTERNATIF 2 (DESA SIMANERE, KECAMATAN GUNUNG SITOLI IDANOI) LEBIH LAYAK UNTUK LOKASI PLTU NIAS SELATAN 2x3 MW.

20 PRAKIRAAN TOTAL KEBUTUHAN AIR PLTU AIR PENDINGIN = 1.200 m 3 /hari AIR DEMIN & SERVICE = 20 m 3 /hari PRAKIRAAN TOTAL KEBUTUHAN BATUBARA SELAMA 1 HARI = 120 Ton SELAMA 1 BULAN= 3600 Ton PRAKIRAAN KEBUTUHAN LAHAN UNTUK COAL YARD AKTIVE STORAGE SELAMA 10 HARI= 0,07 Ha DEAD STORAGE SELAMA 1 BULAN= 0,02 Ha PRAKIRAAN ABU YANG DIHASILKAN SELAMA 1 TAHUN = 2.500,00 Ton LUAS LAHAN YANG DISEDIAKAN = 0,04 Ha INFORMASI UMUM Pltu 2x3 MW

21 KONDISI PEMBANGKIT MARET 2010 PLTD GUNUNGSITOLI Nyalakan Irit Awasi Selebihnya Catatan : DGS-7 & DGS-8 sudah di usulkan menjadi material ATTB rusak karena gempa

22 KONDISI PEMBANGKIT MARET 2010 PLTD TELUK DALAM Nyalakan Irit Awasi Selebihnya

23 KONDISI PEMBANGKIT MARET 2010 PLTD PULAU TELLO Nyalakan Irit Awasi Selebihnya

24 UNIT MESINDAYA (kW) KET MerkTypeNo.SeriTPSGMPU PLTD GUNUNGSITOLI 5MW 1SWD9FHD24070481-212681014DLM PLKS 2SWD9FHD24070481-112681014DLM PLKS 3SWD9FHD2407054612681014DLM PLKS 4SWD9FHD24070481-312681014DLM PLKS 5SWD6FFHD7038931114890DLM PLKS 6SWD6FFHD70389-21114890DLM PLKS JUMLAH73005836 PLTD GUNUNGSITOLI 3MW 1 CTRPILAR750450OPERASI 2 CUMMINS750450OPERASI 3 MTSHBISI8000GANGGUAN 4 PARKINS1000600OPERASI 5 PARKINS10000GANGGUAN 6 CUMMINS800450OPERASI JUMLAH 51001950 PLTD TELUK DALAM 3MW 1CUMMINSKTA 50-G133125558800640OPERASI 2CUMMINSKTA 38-6533148031800640OPERASI 3CUMMINSKTA 50-G233119834800640OPERASI 4CUMMINSKTA 50-G132688937800640OPERASI 5CUMMINSKTA 50-G2331051830800640OPERASI 6CUMMINSKTA 50-G23312815412601008OPERASI JUMLAH 52604208 KONDISI UNIT SEWA 3MW - 5MW PLTD GUNUNGSITOLI DAN PLTD TELUK DALAM

25 KONDISI ANGIN NIAS

26


Download ppt "PLTU 2 x 3 MW NIAS SELATAN SITE SELECTION with PLN CABANG NIAS and PLN Enjiniring 16-20 March 2010."

Presentasi serupa


Iklan oleh Google