PERANGKAT KERAS SCADA LFC PLN (PERSERO) P3B JB BOPS

Slides:



Advertisements
Presentasi serupa
Busbar/Rel Merupakan peralatan tempat pertemuan/hubungan antara trafo-trafo tenaga, Saluran Udara TT, Saluran Kabel TT dan peralatan listrik.
Advertisements

SOP KOMUNIKASI Tujuan Komunikasi Operasi Sistem Sarana Komunikasi
OVERVIEW PMBANGKIT PLTG / PLTGU
Sistem Input/output (I/O)
Organisasi Komputer : Input Output
KURNIA RATMOKO LAHIR : MADIUN, 6 AGUSTUS 1965 MASUK PLN : 1 MEI 1991
Iwan Setiawan Teknik Elektro Undip
PT INDONESIA POWER UBP PRIOK
MENGOPERASIKAN SISTEM KOMPUTER
NoSub Nama ProfesiMateri Soal (7)BasSpeSys 1 Operasi Pembangkitan Thermal (KIT ) Operator PLTGU √ 2Operator PLTP √ 3Operator PLTGU M&G √ 4Operator.
RELAI FREKUENSI ( FREQUENCY RELAY )
Pemrosesan I/O.
TRAFO TRANSFORMATOR TRANSFORMER
GENERATOR PEMBANGKIT TENAGA LISTRIK
Sistem Input/output (I/O)
PT. PLN (Persero) Cabang Samarinda
Distribusi Tenaga Listrik
SISTEM TENAGA LISTRIK Pertemuan 3
MATERI GI & TRANSMISI D-1
TEKNOLOGI PENGOLAHAN GAS BUANG DAN PARTIKULAT Studi Kasus : PLTU/PLTGU/PLTG PT Indonesia Power Unit Pembangkitan Semarang M.ARIEF SETIAWAN NRP
Mengoperasikan PLC pada sistem operasi unit generator pembangkit
Pengenalan Sistem Operasi
Busbar/Rel Merupakan peralatan tempat pertemuan/hubungan antara trafo-trafo tenaga, Saluran Udara TT, Saluran Kabel TT dan peralatan listrik.
Teknik Pembangkit Listrik
Memasang peralatan proteksi
Oleh Umar Muhammad, ST., MT.
MACAM – MACAM ALAT UKUR DAN PENGGUNAANYA
Pengaplikasian PLC Dyah Darma Andayani.
PEMBANGKIT TENAGA LISTRIK
MENGOPERASIKAN SCADA SISTEM PENGOPERASIAN UNIT GENERATOR PEMBANGKIT
M. Hariansyah, lahir di Balikpapan pada tanggal 17 Maret 1968
TRAFO TRANSFORMATOR TRANSFORMER
INSTRUMENTASI KONTROL PROSES
SCADA Pert V (Pengolahan Data )
MEGGER PENGUKURAN TAHANAN ISOLASI
Struktur Sistem Komputer
Transmisi Tenaga Listrik dan Gardu Induk
SISTEM AMF Kontrol Automatic Main Failure (AMF) merupakan unit yang mengendalikan secara automatis mengatasi gangguan saluran utama sistem penyediaan.
Pertemuan VI (Perangkat Lunak) Umar muhammad, MT
PETUNJUK PENGOPERASIAN PANEL LVMSB
Struktur Sistem Komputer
Sistem Traksi PT Len Industri.
STRATEGI PENGATURAN FREKUENSI
WATER LEVEL CONTROL Berbasis SCADA
Manfaat dan Bahaya Listrik
SOSIALISASI MANFAAT & BAHAYA KELISTRIKKAN PLN APP SURABAYA.
SCADA & LFC PLN (PERSERO) P3B UBOS
Load Frequency Control (The Never Ending Story)
Pengantar Pengaturan Primer (Governor Free)
Load Frequency Control (The Never Ending Story)
AGENDA PLTU Paiton Unit 1 dan 2 : -Koordinasi pelaksanaan pengujian P’o Unit 2. -Melaksanakan Pengujian parameter LFC P’o Unit 2 -Melaksanakan Pengujian.
Disusun oleh: Annisa Wigati
Load Frequency Control (The Never Ending Story)
FREKUENSI Frekuensi adalah salah satu besaran listrik yang merupakan gelombang sinusoidal dari tegangan atau arus listrik dalam satu detik dan diukur dengan.
Bands in Frequency of Power System
PERANGKAT KERAS SCADA & LFC PLN (PERSERO) P3B UBOS
LOAD FREQUENCY CONTROL SISTEM JAWA BALI
6. Load Frequency Control
PERANGKAT KERAS SCADA LFC PLN (PERSERO) P3B UBOS
PERANGKAT KERAS SCADA LFC PLN (PERSERO) P3B JB BOPS
FREKUENSI Frekuensi adalah salah satu besaran listrik yang merupakan gelombang sinusoidal dari tegangan atau arus listrik dalam satu detik dan diukur dengan.
PT PLN (Persero) PUSAT PENDIDIKAN DAN PELATIHAN Belajar & Menyebarkan Ilmu Pengetahuan Serta Nilai – Nilai Perusahaan.
PT PLN (Persero) PUSAT PENDIDIKAN DAN PELATIHAN Belajar & Menyebarkan Ilmu Pengetahuan Serta Nilai – Nilai Perusahaan.
SISTEM TENAGA LISTRIK.
HASIL TES RESPON FREE GOVERNOR SERENTAK
LOAD FREQUENCY CONTROL L F C
SISTEM TENAGA LISTRIK.
KOMUNIKASI DATA.
SISTEM KONTROL ROBOTIK
Overview PROSES KELISTRIKAN PROJECT STATEMENT M eningkatkan keandalan pasokan energi listrik dengan meng-interkoneksi-kan seluruh pembangkit di PKG.
Transcript presentasi:

PERANGKAT KERAS SCADA LFC PLN (PERSERO) P3B JB BOPS

LOAD FREQUENCY CONTROL LFC adalah suatu pengaturan frekuensi system tenaga listrik yang dikendalikan secara auto dari control center dengan cara menaik/menurunkan beban suatu Pembangkit melalui peralatan SCADA-Tel.

FUNGSI PENGATURAN Fungsi pengaturan Frekuensi system. Fungsi pengaturan Beban (Power) Fungsi pengaturan Beban & Frekuensi. Untuk SCADA PLN Jawa-Bali menggunakan fungsi pengaturan Frekuensi system ( Load Frequency Control )

FREKUENSI SISTEM TENAGA LISTRIK Hz 50.00 49.50 50.50 49.00 51.00 BEBAN (KONSUMEN) PEMBANGKIT

PENGENDALI FREKUENSI Pengendali Frekuensi UTAMA ( Primary Regulation / Governor Free ) Pengendali Frekuensi KEDUA ( Load Frequency control / LFC )

PENGENDALI FREKUENSI UTAMA ( Primary Regulation ) Adalah pengendali utama dari Unit pembangkit yang cepat bereaksi mengikuti perubahan Frekuensi System. Bertugas mengatasi dinamika beban suatu unit pembangkit dengan cepat sesuai parameter yang ditentukan. Bekerja secara lokal (individu) atas dasar penyimpangan Frekuensi system ( Df ).

PENGENDALI FREKUENSI KEDUA LFC ( LOAD FREQUENCY CONTROL ) LFC adalah pengendali Frekuensi kedua yang bereaksi lebih lambat dari Primary Regulation/Governor Free, tetapi lebih cepat dibandingkan Operator. Bertugas mengatur variasi beban unit pembangkit agar Frekuensi system stabil . Bekerja secara terpusat atas dasar deteksi akumulasi penyimpangan Frekuensi ( Df ) yang dipantau di Control Center. LFC hanya berfungsi pada saat system tenaga listrik kondisi normal. Pada saat Frekuensi melampaui batas bandwith yang telah ditentukan, LFC secara Automatis Off.

N Level Suatu besaran tertentu yang dihasilkan oleh komputer pada pusat kontrol. Berfungsi memberi komando ke Unit Pembangkit untuk menaik/merunkan beban. Makin banyak Unit yang ikut LFC, makin kecil perubahan N level. Dengan perubahan N level yang kecil, berarti Frekuensi makin lebih stabil dan bekerjanya unit pembangkit yang berpartisipasi LFC semakin ringan.

LFC UNIT PEMBANGKIT Pg = P’o + P’r.N BEBAN PEMBANGKIT LFC UNIT PEMBANGKIT Pg = P’o + P’r.N Pg = Power output generator ( actual power ) P’o = Power operation. P’r = + 50% Bandwidth power regulation N = Level ( - 1 s/d + 1 ) k Max P’r + P’o LFC BANDWIDH N POOP/Po PROP/Pr POAQ/P’o PRAQ/P’r Load frequency control N_Level Real power set point Maximum power variation set point Real power setting Maximum power variation setting Analog Signal From JCC P’r - Analog Signal From DCS Min k

SYSTEM LFC JCC 500 kV 150 kV COMPUTER JCC FREKUENSI SYSTEM OPERATOR (DISPATCHER) FRONT-END COMPUTER RTU COMPUTER RCC RTU COMPUTER UNIT PEMB COMPUTER UNIT PEMB 500 kV 150 kV

CONTOH SYSTEM LFC PAITON COMPUTER JCC FREKUENSI SYSTEM OPERATOR (DISPATCHER) FRONT-END COMPUTER RTU 1 RTU 2 GITET GATEWAY GATEWAY POWER PLAN LFC Interface LFC Interface LFC Interface LFC Interface FUTURE Unit 1 Unit 2 Unit 5 Unit 6 Unit 7 Unit 8 Unit 3 Unit 9

GARDU-INDUK RTU CPU CT VT ADC AI TSS ( Alarm ) DI TSD ( CB, PMS ) AO CONTROL CENTER MODEM CPU CT MODEM VT ADC TRANSDUCER ( MW, MX, V, A, Hz ) AI TSS ( Alarm ) DI TSD ( CB, PMS ) AO DCS UNIT PEMBANGKIT C PROSES DO O CD POSISI TAP TRAFO

RANGKAIAN PROSES SISTEM SCADA PLN R T U I T F 1 I T F 2 I T F 3 T D B PANEL CONTROL CONTROL CENTER TM MW MX MD MD CPU KV A RC, TSS, TSD TS Hz RC R TC L ADC TM LFC SERANDANG KE UNIT PEMBANGKIT

LFC PARAMETER DCS RTU/ GATE WAY UNIT MASTER JCC N ( Level ) Po ( MW ) Pr ( MW ) P’o ( TM ) P’r ( TM ) Power ( TM ) LFC Req ON ( RC ) UNIT MASTER JCC RTU/ LFC Req OFF ( RC ) GATE DCS LFC Req ON ( TSD ) WAY LFC Req OFF ( TSD ) LFC ON ( TSD ) LFC OFF ( TSD ) LFC Available ( TSD ) LFC Not Available ( TSD ) LFC Faulty ( TSS ) RTU / GATEWAY Faulty

Interface Control Cubicle LFC HARDWARE (Unit konvensional) Contoh LFC : Muara Karang PLTU 4, 5 Tambak Lorok PLTU 3 Gresik Lama PLTU 3, 4 Operator Plate JCC RTU Relay Transducer Panel MCP ICC Interface Control Cubicle ( Micro-Z ) ( Interface Tambahan ) Relay Panel Catu Daya 48 vDC

Panel Plate Power Factor Meter MCP Muarakarang Unit 4 / 5

Operator Plat LFC Muarakarang Unit 4

LFC ADAPTATION PRINCIPLE DCS LFC ADAPTATION PRINCIPLE SCADA - + RTU / GATEWAY N Po LFC On / Off P’o Pr P’r Actual Power D P > Max P Min Setter GOVERNOR MOTOR ALARM ANALOG, MEMORY 50 Hz Ref Freq. System LFC Req On / Off LFC On / Off Switch LFC Req LFC Ava / N Ava LFC Fail LFC Desk Faulty LFC AVA Yes/No RTU Fail WD LIMITER PULSE GENERATOR FUNCTION THRESHOLD 2 1 DEAD BAND P LOAD LIMITER GOVERNOR NOR Time Relay UNIT CONNECT TO THE NETWORK AND Pr SETTER Po SETTER P Max Setter < Min POWER TURBIN NO P’o + P’r.N + KDF P’o + P’r.N 1=Governor Mode 2=Load Limit Mode

PERSYARATAN MENGHIDUPKAN LFC Unit dalam kondisi baik . Unit tidak posisi “load limit” Unit harus pada “Coordinate Mode” Tidak terjadi Alarm LFC di MCP ( Main Control Panel ) RTU/Gateway komunikasi baik dengan Control center “In Pool” Signal Po, Pr dikirim dari Control Center Signal P’o, P’r dikirim dari MCP. Tidak terjadi discrepancy yang besar antara Po-P’o dan Pr-P’r Signal N_Level dari Control Center tidak blok LFC Request (LFR) dari JCC “ON” LFC Switch ON dari Operator ( MCP )

PEMANTAUAN FREKUENSI JCC GANDUL 500 KV 150 KV VT VT 220 V Indicator Transducer 50.00 GPS GPS MASTER COMPUTER MASTER COMPUTER Recorder FE FE RTU 500 RCC 1,3,4 RTU 150 KV

JARINGAN LFC PLN JAWA-BALI MASTER JCC RCC 3 OPERATOR / DISPATCHER) ( HMI ) FREKUENSI SYSTEM MTWAR Blok 1 1 X 400 SRLYA 5, 6, 7 3 X 600 PLTU TBROK 1 X 200 PLTGU TBROK 2 X 500 PITON 1, 2 2 X 400 CRATA 1 s/d 8 8 X 125 SGLNG 1 s/d 4 4 X 175 RCC 4 PLTGU GRSBR 1 X 600 RCC 1 PLTU MKRNG REPOWERING PLTGU MKRBR 1 X 500 FRONT-END 150 KV 500 KV GRATI Blok 1 TJATI 1, 2 2 X 650 PLTU GRSLM 2 X 200 PLTGU CLGON 2 X 750 GRSIK Blok 2, 3 2 X 600 PITON 9 1 X … PITON 7, 8 PLTGU PRIOK PLTGU CLCAP 2 X PITON 5, 6 PITON 3 Po, Pr, N Po, Pr, N P’o, P’r P’o, P’r

KONDISI LFC JAWA BALI L O K A S 1 SCADA UNIT KETERANGAN 1 SURALAYA 500 kV. Unit 5, 6 & 7. Normal Normal 2 SAGULING 500 kV. Unit 1, 2, 3 & 4. Normal Pr dari JCC semua unit belum dapat dipantau di PH Saguling, karena keterbatasan I/O. UBP Saguling akan mengusulkan pengadaan I/O u/SCADA PACK. 3 CIRATA 500 kV. Unit 1 s/d 8. Normal Normal 4 GRESIK 500 kV. PLGU 2 & 3 Normal Normal 5 PAITON 500 kV. Unit 1 dan 2 Normal Control Unit sering Alarm bila LFC ON LFC sering alarm dan dan dimatikan oleh operator 6 PAITON 500 kV. Unit 5, 6, 7 & 8 SCADA siap sampai di GITET, tapi belum disambung ke masing-masing unit. Belum ada kesepakatan antara PEC, Jawa Power dengan PLN Swasta. 7 GRATI 500 kV. PLTGU 1 Normal Normal 8 MUARA T 500 kV. Block 1 dan 2 Blok 1 Normal Blok 2 SCADA siap belum disambung ke Unit Blok 1 Sudah dilakukan commissioning, tapi sudah lama tidak dioperasikan. Blok 2 LFC belum siap

L O K A S 1 SCADA UNIT KETERANGAN 9 PRIOK BARU 150 kV. PLTGU 1 & 2 Blok 1 normal Blok 2 perlu pengcekan ulang Blok 1 Sudah dilakukan commissioning tapi lama tidak dioperasikan Blok 2 belum pernah operasi 10 MUARA K 150 kV. THERM 4 & 5 Peralatan control (micro Z) tidak dioperasikan. Tidak dapat beroperasi dengan LFC Unit konvensional 11 MUARA K Baru 150 kV. PLTGU 1 Normal Normal 12 GRSIK LAMA 150 kV. PLTGU 3 & 4 Peralatan control (micro Z) tidak dioperasikan. Tidak dapat beroperasi dengan LFC Unit konvensional 13 GRSIK BARU 150 Kv. PLTGU 1 Normal Normal

L O K A S 1 SCADA UNIT KETERANGAN 14 TAMBAK L 150 kV PLTU Unit 3 Peralatan control (micro Z) tidak dioperasikan. Tidak dapat beroperasi dengan LFC Unit konvensional 15 TAMBAK L BARU 150 kV PLTGU 1 & 2 Normal 16 CILACAP 150 kV PLTU 1 & 2 Dalam proses 17 CILEGON BARU PLTU 1 & 2 Dalam proses 18 PLTU TANJUNG JATI PLTU 1 & 2 Dalam proses

JAVA-BALI CONTROL CENTER

TERIMA KASIH